SOLEUS Air Wall Mountable Micathermic Flat Panel Radiator Heater HGW-308R Floor. $89.99 +$49.19 shipping. Make Offer - SOLEUS Air Wall Mountable Micathermic Flat Panel Radiator Heater HGW-308R Floor. Soleus Air FS-40R-A 16-Inch Oscillating Pedestal Fan. Accessibility, User Agreement. Thank you for choosing a Soleus Air Portable Air Conditioner. This owner's manual will provide you with valuable information necessary for the proper care and maintenance of your new product. Please take a few moments to thoroughly read the instructions and familiarize yourself with all the opera-tional aspects of your new Soleus Air Portable.
These files are related to Soleus Air Air Conditioner PH3-12R-03 user manual. Just preview or download the desired file.
Model No. PH3-12R-03
take a few moments to thoroughly read the instructions and familiarize yourself ... tional aspects of your new Soleus Air Portable Air Conditioner with Heat Pump ...
Portable Air Conditioner, Dehumidifier, Heater and Fan utilizing Heat ...
Please read owner's manual carefully before operating unit. ..... you for purchasing the Soleus Air PH1-14R-03/PH1-12R-03 Portable Air Conditioner and Heater.
Soleus Portable Air Conditioner 12000 Btu Manual
(sg-pac-12e1) portable ac owners manual portable air conditioner and ... with heat pump lx-100/lx-100bl/lx-120/lx-120bl operating instructions ph3-12r-03.
Soleus Air Conditioner User Manual
The best ebooks about Soleus Air Conditioner User Manual that you can get for free ... btu portable air conditioner 14,200 btu heat pump ph3-12r-03 operating.
Soleus Air Instructions Wordpress PDF ...
If you came here in hopes of downloading Soleus Air Instructions Wordpress, you ... air ph1 12r 03 manual technology. pe4-12r-0 Soleus air conditioner pe2 10r 32 ... instructions)). soleus black &
Soleus Portable Air Conditioner User Manual
The best ebooks about Soleus Portable Air Conditioner User Manual that you ... soleus~10000~btu~portable~air~conditi oner~manual ph3-12r-03 operating ...
Soleus Air Conditioner User Manual
under topic such as soleus air air conditioner user manual - wcilt packaged ... instructions - air treatment products ph3-12r-03 operating instructions soleus air ...
Download soleus air pe8 11r 32 manual service 614 Pages
air air conditioner manuals manualslib com , soleus air ky5 110 aka pe8 11r 32 ... soleus air ph3 12r 03 user s manual , 11 000 btu portable air conditioner with.
Soleus Air User Manual - enviro
number: hct-d70eip-a (tda70eip) portable portable air conditioner and heater with ... keywiz soleus air lx 140 manual - izouk ph3-12r-03 operating instructions ...
14,000 BTU Portable Air Conditioner
12,000 BTU Heat Pump
LX-140 / LX-140BL
Operating Instructions
Model No. LX-140 | |
® | © 2006 Soleus Air International |
Thank you for choosing a Soleus Air LX-140/LX-140BL Portable Air Conditioner & Heat Pump. This owner’s manual will provide you with valuable information necessary for the proper care and maintenance of your new product. Please take a few moments to thoroughly read the instructions and familiarize yourself with all the operational aspects of your new Soleus Air Portable Air Conditioner with Heat Pump technology.
For your own records, please attach a copy of your sales receipt to this manual. Also, write the store name/location, date purchased, and serial number below:
Store Name: ____________________________________________________
Location: ______________________________________________________
Date Purchased: _________________________________________________
Serial Number (located on back of unit): ______________________________
IMPORTANT INSTRUCTIONS
Before installing and using your portable air conditioner, please read this owner’s manual carefully. Store this manual in a safe place for future reference.
1)Always place the unit on a level surface.
2)Never use or store gasoline or other flammable vapor or liquid near this unit unless instructed by this manual.
3)Maintain at least 10 inches (25 cm) clearance space around this unit. Do not block or cover air inlet or outlet grilles.
4)The unit must be connected to a correctly grounded power supply.
5)Do not start or stop the unit by inserting or pulling out the power plug.
6)Do not use an adapter plug or extension cord.
7)Do not use the unit in the immediate surroundings of a bath, a shower or a swimming pool.
8)Do not insert anything into the air outlet. Do not obstruct air inlet or outlet grills unless instructed by this manual.
9)Do not let children play near this unit.
10)Always inspect the cord for signs of damage before use. If the power cord is damaged, it must be replaced by the manufacturer or a qualified service technician.
11)When cleaning the unit, always turn the unit off and unplug the power cord.
PACKAGE CONTENTS
Portable Air Conditioner Exhaust Hoses (2) Hose Adapters (2) Window Kit Adapter (2) Remote Control
AAA Batteries (2)
Window Kit - 4 Sliding Panels (1 dual hose panel, 1 single hose panel, 2 extension panels) Air Intake and Outlet Covers (2)
Owner’s Manual
SPECIFICATIONS
•The cooling capacity is measured at an ambient temperature of DB 86 °F, WB 78 °F.
•Noise level is measured at a distance of 3.28 ft away from the front of the unit, when the unit is in cooling mode.
•Power consumption is measured when the fan runs at the highest speed setting.
•These specifications are for reference only. For actual data, please refer to the rating label on the back of the unit.
•If the environment temperature is higher than the max operating temperature or lower than the minimum operating temperature, the air conditioner may not work properly.
MODEL | LX-140 / LX-140BL | |||
COOLING CAPACITY | 14,000 BTU/H | |||
HEATING CAPACITY | 12,000 BTU/H | |||
DEHUMIDIFYING CAPACITY | 60 pts/Day | |||
POWER | COOLING | 1350W | ||
HEATING | 1160W | |||
AIR FLOW VOLUME | 225 CFM | |||
POWER SOURCE | 115 V~ 60 HZ | |||
10.5/12 AMP HEATING/COOLING | ||||
SOUND PRESSURE LEVEL | 46 dB(A) | |||
NET WEIGHT | 82 Lbs | |||
OPERATING | COOLING | 60.8 -107.6 | ||
TEMPERATURE | ||||
HEATING | 23 -89.6 | |||
ASSEMBLED | 17.5” W ×32.75” H ×19” D | |||
DIMENSIONS | ||||
PACKAGE | 22.44” W ×34.44” H ×19.88” D | |||
REFRIGERANT | R22 |
3
PRODUCT DIAGRAM
Control Panel
Louvers
Signal Receptor
Casters
Filter Compartment
Air Intake Cover/Filter
PARTS & ASSEMBLY
PARTS
EXHAUST HOSES
WINDOW KIT
ASSEMBLY & INSTALLATION
INSTALLATION
When the unit is operating as an air conditioner, heater, or dehumidifier, the unit draws in fresh outdoor air and exhausts hot air (in AC or dehumidifier mode) or cool air (in Heat mode) out of the room to complete the air exchange. When the unit is operating in fan mode, no outdoor air exchange takes place. The window kit and exhaust hose do not need to be installed when the unit is used as a fan.
NOTE: The supplied window kit can be installed in sliding windows and sliding glass doors up to 8 ft. long (approximate length).
MOUNTING THE EXHAUST HOSES
•Choose a suitable location, near a grounded electrical outlet and suitable window or door. Remove packaging and locate components.
•Extend both ends of the exhaust hoses approximately 6 inches.
•Screw the window kit adapter onto one end of the exhaust hose clockwise. Screw the hose adapter onto the other end of the exhaust hose clockwise. Repeat on the other exhaust hose.
•Remove outlet covers from the back of the unit by screwing them counter-clockwise, then lifting up.
•Mount the exhaust hoses onto the back of the unit by locking the hose adapters into place.
DUAL HOSE WINDOW KIT INSTALLATION - To quickly and efficiently cool a large area.
7
SINGLE HOSE EXHAUST & WINDOW KIT INSTALLATION
When you want quick spot cooling, install the LX-140 / LX-140BL using the single hose window kit installation.
For Single Hose Installation
Install only the left exhaust hose over the circular air outlet (this outlet will be on the left side of the unit when you are facing the back of the unit). Cover the right circular air intake using the exhaust intake cover. After installing the hose remove the square air intake cover on the back of the unit and install the square air intake vent with removable/washable filter.
Exhaust Hose installed onto circular air outlet on left side
Exhaust cover installed over circular air intake on right side
Air Intake Cover | Air Intake Vent |
For Single Hose Window Kit Installation
To install the window kit, follow the same directions on page 6 for dual hose installation, but instead of using the dual hose window kit panel, use the single hose panel pictured below.
Single Hose Window Kit Panel
CONTROL PANEL, DISPLAY, & OPERATING INSTRUCTIONS
CONTROL PANEL & MULTI-COLOR DISPLAY
CONTROL PANEL
TEMP & TIMER SELECTION
POWER BUTTON
MODE BUTTON
TIMER BUTTONS
TEMP SELECT | FAN SPEED BUTTON |
MULTI-COLOR DISPLAY
AUTO | A/C | DEHUM. | FAN | HEAT |
TIMER ON
TIMER OFF
FAN SPEED
TEMPERATURE
AND TIMER
INDICATOR
OSCILLATION ON/OFF COMPRESSOR ON/OFF BUCKET FULL SLEEP MODE ON/OFF
OPERATING INSTRUCTIONS
CONTROL PANEL BUTTONS (Refer to the images on page 8)
1)Power On and Off - Press the POWER button once to manually turn the unit on. Press the POWER button once more to turn the unit off.
2)Mode Selection - Press the MODE Button repeatedly to cycle between the different modes: Auto mode, Air Conditioner, Dehumidifier, Fan only, and Heater.
3)Fan Speed Control - Press the FAN SPEED Button to cycle through the different fan speeds: High, Medium, and low. The fan speed can be visually distinguished by the speed of the digital air segments progressing out from the windmill fan image on the Multi-color display. There is an additional auto speed setting that is enabled in only heating and cooling modes. This speed is next setting after low when pressing the speed control button. The speeds will cycle through in this order: Low, Medium, High, Auto. Each change in speed will be associated with a “beep” sound from the unit.
4)Temperature - Select the desired temperature by pressing either ▼ or ▲ key when using the unit in cooling or heating mode. The temperature indicator flashes to display the desired temperature setting. After the temperature is set, the unit will display this temperature setting until it is changed by the user. The Multi-color display shows temperature in Celsius or Fahrenheit. Press the °F/°C button on the control panel to select the desired temperature setting.
5)Timer - To program the timer, press the TIMER ON button until the display shows a flashing “ ”. Press the ▲ or ▼ buttons to change the clock to the desired time for the unit to automatically turn on. Press the TIMER OFF button and the display on the unit will flash “ ”. Press the ▲ or ▼ buttons to change the clock to the desired time for the unit to automatically turn off. The TIMER OFF indicator will flash for 3 seconds to activate the times you programmed.
NOTE: The timer will also remember your settings when it is set. If you set the timer while in Air Conditioning mode, the timer will automatically turn the unit on and off in air conditioning mode according to the desired programmed times. The timer will also remember the temperature settings, fan speed, and oscillation setting. The timer works when the unit is in Air Conditioner mode, Heating mode, Dehumidifier mode, Fan mode, and Auto mode
OPERATING THE UNIT USING THE CONTROL PANEL
Air Conditioner Mode
1)Install the exhaust hoses and window kit properly (see pages 6 & 7).
2)Plug the Power Cord into an electrical outlet.
3)Turn on the unit by pressing the POWER button on the control panel.
4)Press the Mode button until the “ ” icon appears on the Multi-color display
5)Press the ▲ or ▼ buttons until the desired room temperature appears on the control panel display. The temperature ranges from 61°F - 88 °F (16 °C - 31 °C).
6)Select the desired fan speed by pressing the FAN button.
NOTE: During hot days, the unit will cool the room most efficiently by setting the temperature at the lowest setting and the fan speed on high. Reducing the length of the exhaust duct, insulating the exhaust hose and window kit, and keeping direct sunlight to a minimum will also improve the cooling efficiency.
NOTE: When the unit is running on cooling mode, the exhaust hoses are required and must be vented outside using the supplied window kit.
Dehumidifier Mode
1)Install the exhaust hoses and window kit properly (see pages 6 & 7).
2)Plug the Power Cord into an electrical outlet.
3)Turn on the unit by pressing the POWER Button on the control panel.
4)Press the MODE button until the “ ” appears on the control panel display.
NOTE: The unit operates at low fan speed during dehumidifier mode. The unit cools room slightly during the dehumidification. Keep the windows and doors closed to aid the effectiveness of the unit in removing the moisture from the room.
NOTE: When the unit is running on dehumidifier mode, the exhaust hoses are required and must be vented outside using the supplied window kit.
NOTE: The unit will not perform in dehumidifier mode when the room temperature is lower than 61°F .
Fan Mode
1)Plug the Power Cord into an electrical outlet.
2)Turn on the unit by pressing the POWER button on the control panel.
3)Press the MODE button until the “ ” icon appears on the control panel display.
4)Select the fan speed by pressing the FAN button.
5)To circulate more air, press the SWING button on the remote control. The louvers will oscillate in our exclusive WAVEFLO® pattern; back and forth and up and down, spreading more air throughout the room.
NOTE: It is not necessary for the exhaust hoses and window kit to be installed to operate the unit in fan mode.
Heating Mode
1)Install the exhaust hoses and window kit properly (see pages 6 & 7).
2)Plug the Power Cord into an electrical outlet.
3)Turn on the unit by pressing the POWER button on the control panel.
4)Press the MODE button until the “ “ icon appears on the control panel display.
5)Press the ▼or ▲ buttons until the desired room temperature appears on the control panel display. The temperature ranges from 61°F - 88 °F (16 °C - 31 °C).
6)Select the fan speed by pressing the FAN button. It is recommended to set the fan speed to low.
Soleus Portable Air Conditioner Manual
NOTE: When heat mode is selected, the unit will shut down for 3-5 minutes, then start in heating mode.
NOTE: When the unit is running on heating mode, the exhaust hoses are required and must be vented outside using the supplied window kit.
Auto Mode
1)Install the exhaust hoses and window kit properly (see pages 6 & 7).
2)Plug the Power Cord into an electrical outlet.
3)Turn on the unit by pressing the POWER button on the control panel.
4)Press the MODE button until the “ ” icon appears on the control panel display. Select the fan speed by pressing the FAN button.
NOTE: During AUTO mode, the unit operates in Heating mode when the room temperature is below 68 °F, Dehumidifier mode when the room temperature is between 68 °F to 80 °F. And Air Conditioner mode when the room temperature is above 80 °F.
Sleep Mode (This mode can only be selected when using the Remote control )
1)To set Sleep mode, make sure the unit is in Air Conditioner mode.
2)Press the SLEEP Button on the remote control. The “ ” icon appears on the control panel display.
3)When in SLEEP mode, the fan will run on low to keep fan noise at a minimum.
4)When in Air Conditioner mode, the temperature setting will gradually increase to 2°F above the original set temperature for 6 hours. After 6 hours the temperature setting will return to the set temperature.
5)When in Heating mode, the temperature setting will gradually decrease to 2°F below the original set temperature for 6 hours. After 6 hours, the temperature setting will return to the set temperature.
6)When in Dehumidifier mode, the temperature will not change when Sleep mode is selected.
Compressor Indicator | ||
The “ | ” icon will light up on the control panel display when the compressor turns on. The “ | ” icon will |
turn off when the compressor shuts off. |
Emergency Condensate Holding Tank
When the room temperature is low and the indoor humidity is high, the air conditioner may not be able to evaporate some of the moisture fast enough. When this happens, the water will accumulate in an emergency condensate tank inside the unit. Once the emergency condensate tank is full, the unit will automatically shut
off and the “ ” will appear on the control panel display. To empty the condensate tank, pull the drain plug at the bottom back of the unit. You will need a small pan, approximately 1” high to catch the water coming out of the condensate tank. Once the condensate tank is drained, the unit will begin working within a few minutes. The emergency condensate tank is approximately 1.5 Liters of water. Another option is to purchase a small hose from a hardware store that can fit around the 5/8” drain plug on the back of the unit and drain the unit into a gravity drain or larger pan for continuous drainage. It is not advised to use continuous drainage when the room temperature is higher than 90°F .
REMOTE CONTROL
MODE BUTTON
FAN SPEED
SWING (LOUVER
OSCILLATION)
SLEEP BUTTON
HOUR SELECTER
LCD DISPLAY
POWER BUTTON
TEMP SETTING
TIMER ON
TIMER OFF
MINUTE SELECTER
REMOTE CONTROL OPERATING INSTRUCTIONS
1)Power On and Off - If the unit is already on, press the POWER (I/O) button on the remote while pointing the remote away from the unit. This will turn the remote on. If the unit is off, now press the POWER (I/O) button once to manually turn the unit on. Press the Power button once more to turn the unit off.
When you press the POWER button the upper right square on the remote control LCD Display will light up. When in Air Conditioner, Heating, and Auto mode, the selected temperature will appear on the remote control display. When the unit is in Fan mode and Dehumidifier mode you will see the “- -” icon instead of the set temperature. This shows that temperature selection is not available when the unit is in Fan or Dehumidifier mode.
2)Mode Selection - Press the MODE Button repeatedly to cycle between the different modes: Auto, Air Conditioner, Dehumidifier, Fan only, and Heater mode. The upper left square on the Remote control display will light up showing which mode is selected. In Air Conditioner mode the display will show “COOLING”, in Heating mode the display will show “HEAT”, in Dehumidifier mode the display will show “DRY”, in Fan mode the display will show “FAN”, and in Auto mode the display will show “AUTO”.
3)Fan Speed - Press the FAN speed button to cycle through low, medium, and high fan speeds. The display on the remote control will show LOW, MED, & HIGH under the “SPEED” label on the remote control LCD display. There is an additional auto speed setting that is enabled in only heating and cooling modes. This speed is next setting after low when pressing the FAN speed button on the remote control. The speeds will cycle through in this order: High, Medium, Low, Auto. Each change in speed will be associated with a “beep” sound from the unit. The remote control will not display “AUTO” under the speed label. Once Auto fan speed is selected the unit will beep and there will not be a fan speed displayed on the remote control.
4)Temperature Setting - When the unit is in Air Conditioner or Heating mode you can select your desired temperature. Press the ▲ or ▼ to select your desired temperature setting. The temperature on the LCD display on the remote control will increase or decrease accordingly. Pressing the ▼and ▲ buttons simultaneously will change the temperature select between °F and °C.
5)SLEEP MODE - See “SLEEP MODE” on page 11.
6)SWING - To turn on the exclusive WAVEFLO® oscillation, press the SWING button on the remote control. Once you press SWING, the louvers on the unit will oscillate up and down and back and forth.
The bottom left square of the remote control display will show the “ | “ icon when WAVEFLO® |
oscillation (SWING) is selected. |
7)TIMER - To program the timer, first press the T-ON button. Once T-ON is pressed the auto-on timer will blink in the bottom right rectangle of the remote control display. Press the MIN and HOUR buttons to change the clock to the desired time for the unit to automatically turn on. The minutes will increase by 10 with each press of the MIN button and the hours will increase by 1 with each press of the HOUR button. Press the T-OFF button and the remote control display will flash the desired auto-off timer. Press the MIN and HOUR buttons to change the clock to the desired time for the unit to automatically turn off. The timer is set when the auto-off time stops flashing and the words “ON” and “OFF” are displayed next to the time.
8)CLOCK - To set the clock on the remote control, hold down either the MIN or HOUR button until the displayed time flashes on the remote control display. Change the minutes by pressing the MIN button and change the hours by pressing the HOUR button.
MAINTENANCE
Note: Make sure power is off and the power cord is not plugged into an electrical outlet prior to performing any maintenance on the unit.
Clean or replace filter - If the air filter is blocked with a dust, the airflow volume may reduce. It is recommended to clean the filter once every two weeks or as needed.
1)Remove the filter from the filter compartment on the back of the unit.
2)Wash the air filter by immersing it gently into warm water with a neutral detergent. Rinse the filter and dry it thoroughly out of sunlight.
3)Slide the filter back into the filter compartment after it is thoroughly dried.
4)If the filter is torn or unusable, order a new filter by calling the customer service number on the warranty page of this manual.
Clean the unit Housing
1)Keep the unit from being exposed directly to the sun to prevent color fading.
2)Clean the surface with a damp cloth and dry it with a soft towel.
Storing the Unit for an Extended Period of Time or Transporting the unit
1)Empty any excess water by unplugging the water drainage stop in the back of the unit (located at the bottom).
2)Unplug the unit.
3)The unit should be stored in a cool dry place.
DISCLAIMER
ALL INFORMATION AND THE TECHNICAL SPECIFICATIONS PRESENTED IN THIS USER’S MANUAL ARE THE PRESENTATION OF THE MANUFACTURER. SOLEUS INTERNATIONAL HAS NOT CONDUCTED INDEPENDENT TEST TO THE INFORMATION AND THE SPECIFICATIONS PRESENTED HEREWITHIN.
WARRANTY
One Year Limited Warranty
Soleus International Inc. warrants the accompanying Soleus Air LX-140 / LX-140BL Portable Air Conditioner with Heat Pump technology to be free of defects in material and workmanship for the applications specified in its operation instruction for a period of ONE (1) year from the date of original retail purchase in the United States.
If the unit exhibits a defect in normal use, Soleus International Inc. will, at its option, either repair or replace it, free of charge within a reasonable time after the unit is returned during the warranty period.
Soleus Air Manuals
As a condition to any warranty service obligation, the consumer must present this Warranty Certificate along with a copy of the original purchase invoice.
THIS WARRANTY DOES NOT COVER:
•Damage, accidental or otherwise, to the unit while in the possession of a consumer not caused by a defect in material or workmanship.
•Damage caused by consumer misuse, tampering, or failure to follow the care and special handling provisions in the instructions.
•Damage to the finish of the case, or other appearance parts caused by wear.
•Damage caused by repairs or alterations of the unit by anyone other than those authorized by Soleus International Inc.
•Freight and Insurance cost for the warranty service.
ALL WARRANTIES, INCLUDING ANY IMPLIED WARRANTY OF MERCHANT ABILITY ARE LIMITED TO ONE-YEAR DURATION OF THIS EXPRESS LIMITED WARRANTY. SOLEUS INTERNATIONAL INC. DISCLAIMS ANY LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES AND IN NO EVENT SHALL SOLEUS INTERNATIONAL INC’S LIABILITY EXCEED THE RETAIL VALUE OF THE UNIT FOR BREACH OF ANY WRITTEN OR IMPLIED WARRANTY WITH RESPECT TO THIS UNIT.
Soleus Air Conditioner Manual
This warranty covers only new products purchased from our authorized dealers or retailers. It does not cover used, salvaged, or refurbished products.
As some states do not allow the limitation or exclusion of incidental or consequential damages, or do not allow limitation on implied warranties, the above limitations and exclusions may not apply to you. This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.
For Technical Support and Warranty Service
Please Call (888) 876-5387
Soleus Air Dehumidifier Manual
Or Write To:
Soleus International Inc. 9451 Telstar Ave.
El Monte, CA 91731 USA www.soleusair.com