Back-UPS ® RS/XS 1000 User’s Manual Back-UPS ® RS/XS 1500 1 ® CONTENTS RJ-45 USB RJ-11 RJ-11 2 3 CONNECT BATTERY CARTRIDGE OPERATING ENVIRONMENT 3 4 CONNECT EQUIPMENT / POWER Monitor Printer or Scanner FAX External Disk or CD / DVD Drive Input: 120V 12A, 60Hz Circuit Breaker Push to Reset SURGE ONLY BATTERY BACKUP Computer 5 CHECK. Ask the question you have about the APC Back-UPS 800 here simply to other product owners. Provide a clear and comprehensive description of the problem and your question. The better your problem and question is described, the easier it is for other APC Back-UPS 800. Browse all pages of the user manual APC Back UPS XS 1500, translate them to other languages. In every user manual you will usually find a schematic diagram of APC Back UPS XS 1500 as well as tips for servicing APC Back UPS XS 1500. You will also learn how to configure the device APC Back UPS XS 1500 to suit your requirements.
0017
0017
0017
0017
0017
CONNECT TVSS
Back-UPS
®
RS/XS 1200
User’s Manual
1
®
CONTENTS
RJ-45
USB
RJ-11
RJ-11
2
3
CONNECT BATTERY CARTRIDGE
OPERATING ENVIRONMENT
3
4
CONNECT EQUIPMENT / POWER
Monitor
Printer or Scanner
FAX
External Disk or
CD / DVD Drive
Input: 120V~
12A, 60Hz
Circuit Breaker
Push to Reset
SURGE ONLY
BATTERY BACKUP
Computer
5
CHECK BUILDING WIRING
FAULT INDICATOR
Building
Wiring Fault
Wall
Outlet
Modem/
Phone/Fax
TVSS GND
Building Wiring
Fault Indicator
6
Phone Jack
Computer
Modem Port
CONNECT PHONE/MODEM/FAX
TVSS GND
Wall
Outlet
Wall
Outlet
Modem/
Phone/Fax
7
CONNECT 10/100 Base-T or VOIP
Network Jack
Computer
Network Port
8
To Computer USB
Port
CONNECT INTERFACE
Data Port
BR24BP Battery Pack
Computer
11
INSTALL SOFTWARE ON
COMPUTER
There are four status indicators (lights) on the front
panel of the Back-UPS (On Line, On Battery, Overload,
and Replace Battery).
On Line (green)
- is lit whenever utility power is
Apc Back Ups Xs 800
powering the Battery Backup outlets.
On Battery (yellow)
- is lit whenever the battery of
the Back-UPS is powering equipment connected to the
Battery Backup Outlets.
Four Beeps Every 30 Seconds - this alarm is
sounded whenever the Back-UPS is running On
Battery. Consider saving work in progress.
Overload (red)
- is lit whenever power demand has
exceeded the capacity of the Back-UPS.
Continuous Tone - this alarm is sounded
whenever the Battery Backup outlets are
overloaded.
Circuit Breaker - the circuit breaker button
located on the rear panel of the Back-UPS will
stick out if an overload condition forces the Back-
UPS to disconnect itself from utility power. If the
button sticks out, disconnect non-essential
equipment. Reset the circuit breaker by pushing
the button inward.
Replace Battery (red)
- is lit whenever the battery is
near the end of its useful life, or if the battery is not con-
nected (see above). A battery that is near the end of its use-
ful life has insufficient run-time and should be replaced.
Chirps for 1 Minute Every 5 Hours - this
alarm is sounded whenever the battery has failed
the automatic diagnostic test.
Note: Allow the Back-UPS to charge for a full
eight (8) hours prior to use.
Press the front panel Power ON/OFF switch and
observe that the following events occur after
pressing and releasing the switch:
• The green On Line indicator flashes.
• The yellow On Battery indicator lights while
a Self-Test is being performed.
• When Self-Test has successfully completed,
only the green On Line indicator will be lit.
• If the internal battery cartridge is not
connected (see Step 2 above), the green On
Line indicator and red Replace Battery
indicators will light. The Back-UPS will also
emit a chirping sound.
Continuous Beeping - this alarm is sounded
whenever a low battery condition is reached.
Battery run-time is very low. Promptly save any
work in progress and exit all open applications.
Shutdown the operating system, computer and
the Back-UPS.
If Autoplay is not enabled on the computer, proceed
as follows:
1. On the computer desktop of the display, double-
click on My Computer.
2. Double-click on the CD-ROM drive icon and
follow the on-screen instructions.
If the rear panel Building Wiring Fault (red)
indicator is lit, a potential shock hazard exists
due to one of the following conditions:
• Open or high resistance ground
• Hot or neutral polarity reversed
• Overloaded neutral circuit
Improper building wiring should be
corrected by a qualified electrician. Do not
use the Back-UPS until the condition that
caused the fault is corrected.
Note: Improper building wiring will not
prevent the Back-UPS from operating, but it
will limit its protection capability.
9
SWITCH ON THE BACK-UPS
Back Ups Xs 1000 Manual
10
ORIENTATION
12
GROUND
The Back-UPS features a transient
voltage surge-suppression (TVSS)
screw for connecting the ground
lead on additional surge
suppression devices such as
network and data line surge
protectors.
Wall
Outlet
Modem/
Phone/Fax
TVSS GND
From Data Line
TVSS
Follow the
on-screen
instructions.
On Line
On Battery
Overload
Replace Battery
w
w
w.apc.com
®
RJ-45
USB
10/100 Base-T
VOIP
STATUS INDICATORS AND ALARMS
For connection of APC’s optional
external 24-volt battery pack
(BR24BP) to the Back-UPS RS/XS 1500.
(Back-UPS RS models only)
CABLE
32 - 104
o
F (0 - 40
o
C)
001b
0017
0017
0017