Apc Backup Ups Es 750 Users Manual

APC BACK-UPS ES 10 Outlet 750VA 120V, 100V, Master Control Add to My Documents OLD APC BACK-UPS ES 10 Outlet 750VA 120V, 100V, Master Control (Version 0). ® ® Back-UPS ES 725 User’s Guide w w w.apc.com Connect Battery For safety, the Back-UPS ES is shipped with one battery wire disconnected. The UPS will not operate until the wire is connected to the touch-safe battery terminal. NOTE: Small sparks may occur during battery connection. This is normal.

Advertising

Back-UPS ES 350/500

User’s Guide

1

2

3

Connect Battery

Connect
Equipment

Power On and
Install Software

990-9197 Revision 1 11/01 Copyright © 2001 American Power Conversion Corp.

All other trademarks are property of their respective owners.

The Back-UPS ES is shipped with one battery wire disconnected in compliance with Department of Transportation (DOT) regulations. The Back-UPS ES
will not operate until the wire is connected to the touch safe battery terminal.

NOTE: Small sparks may occur during battery connection. This is normal.

1

Apc Backup Ups Es 750 Users Manual

2

4

TURN the Back-UPS ES over and
remove the battery compartment
cover screw using a flat blade or
phillips-head screwdriver.

Slide the battery
compartment cover
completely off of
the Back-UPS ES.

Replace the battery,
battery compartment
cover and cover
retaining screw.

Surge Protection

These outlets provide full-time protection from surges even if
the Back-UPS ES is switched OFF. Plug your printer, fax
machine, scanner, or other peripherals that do not need
battery power into these outlets.

Battery Back-up

plus Surge Protection

These outlets are powered whenever the Back-UPS ES is
switched ON. During a power outage or other utility problems
(brownouts, over-voltages), these outlets will be powered for a
limited time by the Back-UPS ES. Plug your computer, monitor,
and one other data-sensitive device (external disk or tape
drive) into these outlets.

Connect FAX/Modem/Phone

Back-UPS ES protects a single
line (2-wire) fax, modem or
phone from surges when it is
connected through the Back-
UPS ES as shown.

Place the Back-UPS ES to avoid:

- Direct sunlight
- Excessive heat
- Excessive humidity or contact with fluids

Plug the Back-UPS ES power cord directly
into a wall outlet; not a surge protector or
power strip.

Connect Computer Cable

The supplied cable and software provide
automatic file saving and shutdown of the
operating system in the case of a sustained
power outage.

Connect the cable to the Data Port of the Back-
UPS ES. Connect the other end of the cable to
the USB port on your computer. The software will
automatically find the USB Port of your
computer.

Press the ON/OFF switch to power the unit
ON.

A single short beep and the green “Power On”
indicator confirms that Back-UPS ES is on and
ready to provide protection.

The Back-UPS ES should charge for at least
16 hours to ensure sufficient runtime. The unit
is being charged whenever it is connected to
utility power, whether the unit is turned ON or
OFF.

If the red Building Wiring Fault indicator
(located on the end near the power cord) is lit,
your building wiring presents a shock hazard
that should be corrected by a qualified
electrician.

Install the PowerChute Personal

®

Edition

software

Place the PowerChute Personal Edition CD-
ROM into your computer and follow the
installation instructions on the screen.

3

LIFT the battery out of the compartment and connect the
black wire to the battery terminal.

www.apc.com

®

P o w e r O n

Battery Backup

plus Surge Protection

Wall Outlet

Modem/Phone/Fax

Computer

USB Port

Surge Protection

Back-UPS ES 500

Back-UPS ES 350

APC, Back-UPS and PowerChute are registered trademarks of American Power Conversion Corp.

The Back-UPS ES indicates operating status using a combination of visual and audible indicators.

Status

Visual Indications

Audible Indication

Alarm Terminates

When

On Line - UPS is supplying conditioned
utility power to the load

Power On LED - ON

None

n/a

On Battery - UPS is supplying battery
power to the load connected to the
Battery outlets

Power On LED - ON
(off during beep)

Beeping 4 times
every 30 seconds

UPS transfers back to
On Line operation, or
when UPS is turned
off.

Low Battery Warning - UPS is supplying
battery power to the load connected to
the Battery outlets and the battery is near
exhuastion

Power On LED -
Flashing

Rapid beeping (one
second intervals)

UPS transfers back to
On Line operation, or
when UPS is turned
off.

Replace Battery - Battery needs to be
checked and/or replaced, or battery is not
connected

Power On LED -
Flashing

Constant tone

UPS turned off with
the power switch.

Overload Shutdown - During On Battery
operation a battery power supplied outlet
overload was detected.

Power On LED - OFF

Constant tone

UPS turned off with
the power switch.

Sleep Mode - During On Battery
operation the battery power has been
completely exhausted and the UPS is
waiting for utility power to return to
normal.

Apc Back-ups Es 750 Instructions

Power On LED - OFF

Beeping once every
4 seconds

UPS transfers back to
On Line operation, or
when UPS is turned
off.

Building Wiring Fault - Your building
wiring presents a shock hazard that
should be corrected by a licensed
electrician.

Building Wiring Fault
LED (red) - ON

Apc Backup Ups Es 750 Replacement Battery

None

UPS is unplugged, or
plugged into a
properly wired outlet.

Status Indications

Power On

Circuit

Breaker

AC Line

Cord

Building Wiring

Fault Indicator

UPS Power

On Indicator

Power

Switch

®

See the Troubleshooting section for additional assistance.