STEP 4 - TURNING ON YOUR MONITOR
Angelcare AC401 (Baby Monitor): 4 out of 5 stars from 95 genuine reviews on Australia's largest opinion site ProductReview.com.au. Angelcare Deluxe Movement Monitor User Manual CLICK HEREmonitor stops detecting movement, possibly because of the baby not Angelcare Baby Monitor Instructions Photo Credit Stockbyte/Stockbyte/Getty. We ended up buying the Angelcare Movement and Sound Monitor Deluxe Setting up the monitor was pretty.
If there is a lost connection
between the 2 units
(refer to troubleshooting):
• The
Out-of-Range icon
will appear on the screen and
the Parent Unit will beep.
1) Press the Parent Unit ON/OFF button
to open and display normal mode.
2) Push and hold the Nursery Unit
left ‘wing’ button for 2 seconds.
1
When the Parent Unit is turned
ON and the Nursery Unit is OFF,
the Parent Unit will be searching
for connection with the Nursery
Unit. The Connection icon will scan
as the following cycle.
The LCD monitor has 30 seconds
timeout to go to power saving
mode (dimmer illumination).
Press any keys to wake up.
Temperature icon:
Indicates room temperature
Battery Level icon:
Indicates battery level
Empty
1/3 Full
2/3 Full
Full
Settings Icons: Access to settings
VOX icon: Indicates Vox function
is active (Voice activation)
ECO icon: Indicates ECO function
is active
Temperature Alarm icon: Indicates
Temperature Alarm is active
IMPORTANT ICONS
Sound icon: Indicates sound
is active
Sensor Pad icon: Indicates
the Movement Sensor is active
Pendulum icon: Indicates
the ‘TIC’ function is active
Level Bar: Indicates sound level
from Nursery Unit.
Connection icon: Indicates
the connection quality between
the Parent Unit and Nursery Unit.
Good connection
Fair connection
Poor connection
Out-of-Range
2
STEP 5 - TESTING AND GETTING TO KNOW YOUR MONITOR
The Angelcare
®
monitor can be used with the pre-program factory settings
or you can also customize your settings to your preference.
5.1 - SENSOR PAD
1) Press Sensor Pad icon to activate
or
deactivate movement mode.
1) Move your hand lightly on the mattress.
2) Remove your hand from the mattress.
After 15 seconds you will hear a
‘TIC’ pre-alarm sound, and 5 seconds
later the Movement Alarm will trigger.
3) Repeat by moving your hand lightly
in all four corners of the mattress.
Ensure the Nursery Unit Movement
Indicator is still flashing.
IF THE ALARM DOES NOT SOUND
• Avoid contact with crib while Sensor Pad is in operation.
• Place crib near a supporting wall.
• Adjust the Sensor Pad sensitivity level.
ON
OFF
1
2
TO ACTIVATE THE SENSOR PAD:
TO TEST THE SENSOR PAD:
MOVEMENT ALARM
• Alarm activates when no movement is detected by Sensor Pad for 20 seconds.
• Both the Parent Unit and Nursery Unit speakers will emit loud warning sound.
• Movement Alarm icon will show on the LCD screen.
1
When the movement mode is OFF
the ‘TIC’ mode is automatically set OFF.
This allows you to detect the
baby’s
sounds ONLY.
IMPORTANT
When in settings mode, sound
transmission between Parent and
Nursery Units will be temporarily
deactivated. ONLY the movement
alarm will remain active
(if function is activated).
NOTE: All changes
and adjustments made
in the settings mode will
not be activated unless
you confirm them by
pressing the Return icon.
A long beep will confirm
your modification.
15
14
16.10 DO NOT attempt to rejuvenate the
batteries provided with or identified for
use with this product by heating them.
Sudden release of battery electrolyte may
occur, causing burns or irritation to eyes
or skin.
16.11 If and when necessary, the batteries
must be replaced with identical new ones
or equivalent (volts and size). If a battery
to be replaced is connected with other
batteries in series, replace the other
batteries at the same time as well. DO
NOT mix old and new batteries.
16.12 Reverse polarity installation of the
batteries in the end product must be
avoided. Reverse insertion of batteries
can cause charging, and that may result
in leakage or explosion.
16.13 Remove batteries from this product
if you store the product over 30 days
because the batteries could leak and
damage the product.
16.14 Discard ‘dead’ batteries as soon as
possible since ‘dead’ batteries are more
likely to leak in a product. If a battery has
leaked or vented, it should be replaced
immediately using protective gloves.
16.15 DO NOT store this product, or the
batteries provided with or identified for
use with this product, in high-temperature
areas.
WARNING
(North America Only)
17.1 Modifications not authorized by the
manufacturer may void users authority to
operate this device.
17.2NOTE: This equipment has been tested
and found to comply with part 15 of the
fcc Rules and the Industry canada licence-
exempt RSS standard(s). These limits are
designed to provide reasonable protection
against harmful interference in a residential
installation. This equipment generates, uses
and can radiate radio frequency energy
and, if not installed and used in accordance
with the instructions, may cause harmful
interference to radio communications.
17.3 However, there is no guarantee that
interference will not occur in a particular
installation. If this equipment does cause
harmful interference to radio or television
reception, which can be determined by
turning the equipment Off and ON, the
user is encouraged to try to correct the
interference by one or more of the following
measures:
• Reorient or relocate the receiving
antenna.
• Increase the separation between the
equipment and receiver.
• connect the equipment into an outlet on
a circuit different from that to which the
receiver is connected.
• consult the dealer or an experienced
radio/TV technician for help.
17.4 This device complies with part 15 of
the fcc Rules and the Industry canada
licence-exempt RSS standard(s). Operation
is subjected to the following two conditions:
(1) This device may not cause harmful
interference, and
(2) This device must accept any interference
received, including interference that may
cause undesired operation.
IMPORTANT
place the crib near a supporting wall and
far from air currents. Install the Nursery
Unit on a flat, stable surface facing the crib
at a distance of at least 1 meter.
YOU MUST PREPARE:
One hardboard (not included)
Thickness:
6 mm
Minimum dimensions:
33 cm x 33 cm
Maximum dimensions:
equal to the mattress size
WHAT YOU WILL NEED (NOT INCLUDED):
1 parent Unit (Ac401)
or 2 parent Units
(Ac401-2pU and
Ac401-2pU-2Sp)
charging cradle
Hardboard
2 Ac Adapters (Ac401)
or 3 Ac Adapters
(Ac401-2pU and
Ac401-2pU-2Sp)
Nursery Unit
1 Sensor pad (Ac401) or
2 Sensor pads
(Ac401-2pU-2Sp)
with pre-installed cord covers
Miniature philips
Screwdriver
4 Rechargeable AAA Batteries (Ac401)
or 8 Rechargeable AAA Batteries
(Ac401-2pU and Ac401-2pU-2Sp)
for parent Unit
4 AAA Alkaline
Batteries
for Nursery Unit
MOVEMENT &
SOUND MONITOR
Model AC401
IMPORTANT
The hardboard must be larger than the
Sensor pad surface area or in the case of
the Ac401-2pU-2Sp of two Sensor pads.
BABY’S ROOM:
SETUP REQUIREMENTS
4X
INCLUDED:
FCC AND IC REGULATIONS
RF radiation exposure statement
The Nursery Unit complies with fcc Rf radiation exposure limits set forth for an uncontrolled
environment. caution: To maintain the compliance with the fcc’s Rf exposure guideline,
install the Nursery Unit at least 20 cm from from ALL persons. The transmitter of this device
must not be co-located or operating in conjunction with any other antenna or transmitter.
Industry Canada
This product meets the applicable Industry canada technical specifications.
cAN IcES-3 (B)/NMB-3 (B)
6
5
4
Angelcare Movement And Sound Monitor
3
2
1
Keep
at least
1 m
IMPORTANT
6
5
4
3
2
1
Sensor pad(s)
7
6